Measure plateau pressure during an inspiratory hold (0.5-2 sec pause at end-inspiration) to assess alveolar overdistension risk. Goal <= 30 cmH2O per ARDSNet protocol. Values > 30 cmH2O require tidal volume reduction or other interventions.